方舟

How to maintain the working efficiency of closed cooling tower?


Release time:

2022-11-30

The closed cooling tower shall contact the coil fan with water to ensure the cooling target according to the heat value of the cooling steam consumption rate in the wall thickness heat conduction fan coil in the subtropical climate. The refrigeration cooling circulating water in the closed cooling tower only conducts vapor heat conduction inside the cooling tower, and then contacts with the coil fan to obtain the heat value of the steam consumption rate in the fan coil, and the moisturizing and water make-up pipe should properly moisturize and replenish water. Compared with the open cooling tower, the distinctive feature of the closed cooling tower is to improve the coil fan. The steel circulation in the steel coil fan does not directly contact with water, and the heat conduction is conducted according to the wall thickness. In the whole process of actual maintenance, anti-corrosion paint or lubricating grease must be treated for rust prevention or maintenance.

The closed cooling tower shall contact the coil fan with water to ensure the cooling target according to the heat value of the cooling steam consumption rate in the wall thickness heat conduction fan coil in the subtropical climate. The refrigeration cooling circulating water in the closed cooling tower only conducts vapor heat conduction inside the cooling tower, and then contacts with the coil fan to obtain the heat value of the steam consumption rate in the fan coil, and the moisturizing and water make-up pipe should properly moisturize and replenish water.
Compared with the open cooling tower, the distinctive feature of the closed cooling tower is to improve the coil fan. The steel circulation in the steel coil fan does not directly contact with water, and the heat conduction is conducted according to the wall thickness. In the whole process of actual maintenance, anti-corrosion paint or lubricating grease must be treated for rust prevention or maintenance.
Along with the actual treatment, the airtightness of the plastic film may occur after the relevant treatment. In addition, there is also a multi-dimensional inspection of the automobile oil of the reducer. In this case, multi-dimensional maintenance can be carried out. It is reasonable to carry out multi-dimensional maintenance and adjustment of the lubricating grease or anti-corrosion paint, so that there can be a stronger application standard.
The reasons for the reduction of the working efficiency of the closed cooling tower include that the coil fan scaling damages the heat conduction power, the filler scaling and sludge fouling block the filler damage the water diffusion and air circulation, the exhaust window stains and floating flocs chemical substances block the air circulation, the stainless steel sink stains and sludge too much block the spray pump filter screen, the printer nozzle is blocked, and the water dispersion is damaged, which must be professionally removed by mechanical equipment.
According to the above various factors, the anti-corrosion masculinized scale remover plus human resources can be used for removal, and the initial setting ro reverse osmosis reverse osmosis scale inhibitor can be used for maintenance to ensure high removal efficiency; The looseness of belt of centrifugal fan and the airtight leakage of motor will damage the power of mechanical equipment. Check on time and dismantle prefabricated components to maintain high efficiency.
The dirt in the cooling circulating water pipe of the closed cooling tower can not be ignored, which not only damages the cooling power, but also continues to damage the power of the upstream, midstream and downstream heat exchangers, and more seriously, it will lead to the blockage of the heat exchanger, which will lead to the ultra-high pressure safety production accident of the heat source.